Downloads

Current software versions / updates


KOSMIK

KOSMIK 170/210/250 HV / HV-I:

In the firmware version V1.25 for the KOSMIK 170/210/250 HV-I the following item has been added.

  1. Implementation of the telemetry output for the temperature sensor of the Project ONE engine.
    a) Telemetry protocols implemented: Jeti, Graupner and PowerBox.
    b) Mikado, Futaba, FrSky and Multiplex will be added in a later software, we apologize.

No bootloader update is necessary for V1.25, provided V1.17 or higher is installed on your controller. If a lower version than V1.17 is on your controller, the bootloader update must be performed in advance as described below and only then the V1.25 update must be performed.

1. install the bootloader update V1.1 to the controller with the ProgUnit. ATTENTION: When starting the update, the error message will appear that the software is older than the software present on the KOSMIK. Confirm here with “Yes” and perform the update.
After the update is finished, unplug the battery.
IMPORTANT: Connect the motor and receiver.
Reconnect the battery.
Wait until the controller beeps.
Check the version of the boot loader with ProgUnit: If V2.2 appears, the update has been completed successfully.

Notice:
– The bootloader update V1.1 updates the bootloader and does not contain any additional functions!
– When the new software V1.25 is installed, it can also be seen that the bootloader version is now 2.2 and the bootloader update was thus successful.

Firmware V1.25

Bootloader

KOSMIK 160/200

KOSMIK 200 Firmware V4.17

KOSMIK 160 Firmware V4.17

KOLIBRI

KOLIBRI 60/90/140 LV/LV-I & 90/140 HV-I

In firmware version V3.5 for the KOLIBRI models, the following point has been adjusted:

  • A specific section has been modified for Mikado to ensure correct recognition of the battery ID.
  • The output of the RPM in the FrSky telemetry has been fixed and is now displayed correctly on the remote control.

No bootloader update is required for V3.5, provided that V3.3 with the corresponding bootloader V3.1 is already installed on your controller. If a version lower than V3.3 is present on your controller, the bootloader update must be carried out according to the following instructions.

  1. Update firmware as usual with the ProgUNIT.
  2. After the update is complete, disconnect the drive battery.
  3. Connect the controller to the motor and receiver.
  4. Program mode 1.
  5. Disconnect the drive battery.
  6. Connect the drive battery and wait until the controller initializes.
  7. Press and hold the button until the controller beeps (this may take several seconds). The beep of the bootloader update is different from that of the mode programming and is therefore easily recognizable.
  8. Disconnect the drive battery and reconnect it. The controller then initializes and is ready for the user-defined setting.
  9. The controller software V3.5 and bootloader V3.1 are now displayed in K-Config V1.3.11 for checking purposes.

PROGDISC / ProgUNIT

ProgUNIT

Here you can find the current software version of ProgUNIT.

Attention: Please do not install the software of the PROGDisc on the ProgUNIT or vice versa.

PROGDISC

With this update, the PROGDISC is optimized for the latest generation of the KOBY series.

Instructions

Instructions controller

Instructions motors

Instructions accessories

Support


Price list

For all print media, please use the eps file (freely scalable without quality loss):

For all online/screen applications please use the png file (NOT scalable)

We will gladly send you our logo according to your requirements (length x width, file format). Please write us a short message for this purpose.

Software


KONTRONIK address assignments for telemetry

Data Explorer

Here you will find DataExplorer (version 3.3.8), a software to display the SD card data.

K-Config

PC software (Windows™) for ProgUNIT and PROGDISC

Software version 1.3.11 is required to set up the KOLIBRI LV-I or HV-I with software V3.0 and to load saved controller setups.

Archive


Software

KOSMIK

COOL KOSMIK 250/300 HV – Version 1.2.

Motor current warning adapted for Graupner telemetry

KOSMIK 160/200 – version 4.15 and KOSMIK 250/300 – version 1.1

The new software enables the use of the updated Data Explorer to read the data from the SD card.

KOSMIK 160/200

Version 4.14

  • Capacity measurement was optimized
  • Mode 7 (Reverse rotation) was added
  • JETI protocol has been adapted (now also compatible with R-EX, REX and REX-Assist receivers)
  • Futaba protocol adapted (now also compatible with Futaba CGY760R)
  • KONTRONIK protocol was changed: CRC check adapted

Version 4.13

  • Bugfix: Graupner HoTT telemetry – capacity limit warning when Bluetooth module is plugged in

Version 4.12

Version 4.10

  • supports the use of the TelMe JETI and MIKADO.

Version 4.9

  • supports the use of the TelMe Futaba for the FX 22, T18MZ, T18MZ-WC and T14SG. It also enables operation with HV LiPos with a charge termination voltage of up to 4.35 V.

Version 4.8

  • supports the use of the new TelMe-Futaba.

Version 4.6

  • With the current K-Konfig interface, we can offer you new programming options, such as entering the values for your alarms. The restart time after bailout was shortened depending on the set ramp-up time to ensure timely restart even with long ramp-up times. The calculation of the withdrawn capacity has been optimized. To be able to use the parameters, the new K-Config interface is mandatory. If ProgDISC is used, an update must also be performed for it.

Version 4.5.1

  • Elimination of the problem with writing log files to Micro SD cards
  • Mode 10 guide


If your KOSMIK does not work after the update, please proceed as follows:
1. reset of the controller
2. re-installing the current software
If your KOSMIK still does not work after this, you will unfortunately have to send it in for repair. Please do not forget to enclose our service form.

KOLIBRI

KOLIBRI software version V3.3

The new software enables active protection of the KOLIBRI’s electronic components during rapid load changes and avoids false overcurrent fault detection.
In the event of a short-term motor blockage, for example, the current is reduced to zero. After removing / releasing the blockage, the controller continues operation. A hard shutdown due to the current is no longer necessary.

After the successful firmware update, a bootloader update must also be performed as described below.

  1. Update firmware as usual with the ProgUNIT.
  2. After the update is complete, disconnect the drive battery.
  3. Connect the controller to the motor and receiver.
  4. Program mode 1.
  5. Disconnect the drive battery.
  6. Connect the drive battery and wait until the controller initializes.
  7. Press and hold the button until the controller beeps (this may take several seconds). The beep of the bootloader update is different from that of the mode programming and is therefore easily recognizable.
  8. Disconnect the drive battery and reconnect it. The controller then initializes and is ready for the user-defined setting.
  9. For control purposes, the controller software V3.3 and bootloader V3.1 are now displayed in K-Config V1.3.11.

KOLIBRI 60 LV-I
KOLIBRI 90 LV-I
KOLIBRI 140 LV-I

KOLIBRI 90 HV-I
KOLIBRI 140 HV-I

KOLIBRI software version V3.0

For all KOLIBRI models (HV-I and LV-I) we have now made the new software V3.0 available for download. The new software V3.0 is a milestone in the performance of KOLIBRI controllers! The most important thing in advance: it includes several new and adapted safety features – to keep your model on top!

The new KOLIBRI security features in detail:

Intelligent Current Commander – The intelligent current control
In case of prolonged overload up to 1.5 times the rated current, a moderate current reduction to the rated current of the controller occurs after 2 seconds. This ensures flight capability up to the thermal limit and prevents the controller from shutting down due to an overcurrent.

Intelligent Temperature Commander – The intelligent temperature control
When the permissible temperature limit of 90°C is exceeded, there is no abrupt shutdown or shutdown of the controller, but a reduction of the current. The longer the temperature is higher than 90°C, the more current is reduced, down to the maximum possible power of 40% of the rated current. Even in this control state, the KOLIBRI still allows short-term peaks, which avoids unwanted control behavior. Thanks to the intelligent temperature control, the extreme temperature limit of 120°C is not even reached during normal cooling.

Undervoltage / capacity regulation
The settling time when the battery reaches the undervoltage limit has been increased to 2 minutes to allow a relaxed and safe landing.

With the V3.0 software, convenient, direct parameterization via the remote control “VBAR Control Touch” or “VBAR Control Classic” is now also possible. This offers the great advantage of being able to try out different settings of the controller on the flying field!

Other telemetry adjustments:

Default telemetry protocol has been changed to “Mikado”.

If the telemetry protocol “Mikado” is loaded, the stick travels are automatically set to fit “Mikado”. These now no longer have to be taught in.

For “FrSky” telemetry, additional values have been implemented for the freely adjustable telemetry channels of the “FrSky” remote controls. For this purpose the table for naming and correct selection of the IDs is important, which is stored on the KONTRONIK homepage under “Downloads / Software / KONTRONIK address assignment for telemetry”.

With the “PowerBox” telemetry, the set reduction ratio is now calculated in the speed output.

New bootloader

With the new bootloader, sending in a KOLIBRI controller for service in case of an unintentional interrupted or incomplete update is history!

In order to use the new bootloader, the new controller software V3.0 must be installed on the KOLIBRI. Then the bootloader update to V3.0 must be performed as described below. The new bootloader is not backward compatible.

  1. Update firmware as usual with the ProgUNIT.
  2. When the update is complete, disconnect and reconnect the drive battery.
  3. Program the mode 1.
  4. Disconnect the drive battery and reconnect it.
    Wait until the controller initializes.
  5. Press and hold the button until the controller beeps (this may take several seconds). The beep of the bootloader update differs from that of the mode programming and is therefore easily recognizable.
  6. Disconnect the drive battery and reconnect it. The controller then initializes and is ready for the user-defined setting.
  7. For control purposes, the controller software V3.0 and Bootloader V3.0 are now displayed in K-Config V1.3.11.

KOLIBI 90/140 HV-I

KOLIBRI software versionVersion 1.2

  • In version 1.2, a peak current control parameter has been integrated to improve the performance of the controller. The telemetry functions have also been expanded. With software function 1.2, data exchange is possible with:
    • PowerBox
    • FrSky
    There are some special features to note with this software update. When downloading the software update, the virus scanner may report a virus. The software has been checked by KONTRONIK and is definitely virus-free, so the virus message can be ignored. KONTRONIK will make every effort to find a solution as quickly as possible. To avoid errors and malfunctions during the update, the update procedure must be carried out as described below: Attention: For steps 1, 3 and 5 please make sure that the battery voltage is present without interruption, otherwise the bootloader may be damaged and sending the controller to KONTRONIK is inevitable! 1. update firmware, as usual with ProgUNIT. After the update is complete, unplug the drive battery and plug it in again. 3. program mode 1. Unplug the drive battery and plug it in again. Wait until the controller initializes. Press and hold the button until the controller beeps (this may take several seconds). The beep of the bootloader update is different from that of the mode programming, so it is easily recognizable. Unplug the drive battery and plug it in again, the controller initializes and is now ready for user-defined settings. For all users who do not use ProgUnit but would still like to use the update, we offer to install the update free of charge at the KONTRONIK factory. Please simply send the controller together with the KONTRONIK service form to the following address

KOLIBI 60/90/140 LV & LV-I


Software version 2.1

With the update of the software to version 2.1, the telemetry port and the Bluetooth function on the KOLIBRI LV-I can now be used simultaneously.

With the previous software version, the Bluetooth function was only usable when the telemetry cable was disconnected. This improvement is significantly important for the KOLIBRI 140 LV-I, as it has two telemetry ports.

IMPORTANT: If version 2.0 is already installed on the KOLIBRI LV-I controller, this is a normal update and can be performed as described in the instructions. If an older software version than version 2.0 is installed, the update must be installed on the controller as a bootloader update. The procedure for the bootloader update is described in detail for version 2.0 or also in the manual under point 8.Update, number 12.

Software version 2.0

With the software update, we have integrated two new parameters for dynamic current control and peak current control into the boot loader to further improve the performance of the controller.

The telemetry functions have also been expanded. With the software function 2.0 the data exchange with Futaba CGY760 and JETI CentralBOX has been improved. In addition, the telemetry function can now also be used with the systems

  • PowerBox
  • FrSky

There are some special features to note with this software update.

When downloading the software update, the virus scanner may report a virus. The software has been checked by KONTRONIK and is definitely virus-free, so the virus message can be ignored. KONTRONIK will make every effort to find a solution as quickly as possible.

To avoid errors and malfunctions during the update, the update process must be carried out as described below:

Attention: For steps 1, 3 and 5 please make sure that the battery voltage is applied without interruption, otherwise the bootloader may be damaged and sending the controller to KONTRONIK is inevitable!

1. update firmware, as usual with ProgUNIT.

After the update is complete, unplug the drive battery and plug it in again.

3. program mode 1.

Unplug the drive battery and plug it in again. Wait until the controller initializes.

Press and hold the button until the controller beeps (this may take several seconds). The beep of the bootloader update is different from that of the mode programming, so it is easily recognizable.

Unplug the drive battery and plug it in again, the controller initializes and is now ready for user-defined settings.

For all users who do not use ProgUnit but would still like to use the update, we offer to install the update free of charge at the KONTRONIK factory. To do this, please simply send the controller together with the KONTRONIK service form to the address given.

Version 1.4

The KOLIBRI LV-I controllers have so far outputted a voltage of 9V until initialization. This is not a problem for all receivers and FBL systems known to us. However, if pilots still use 6V servos, these could be damaged in the worst case according to our findings.

With version V1.4 we have now programmed our software so that the KOLIBRI LV-I controllers no longer start with a voltage peak, but also go into BEC voltage control before initialization. The BEC voltage set by the user is thus continuously output by the KOLIBRI LV-I controller, even before initialization.

This means that the minimum BEC voltage now also corresponds to the voltage that actually occurred in flight.

There are some special features to be considered for this software update, therefore the update procedure should be carried out as described below: Attention: For steps 1, 3 and 5 please make sure that the battery voltage is applied without interruption, otherwise the bootloader may be damaged and sending the controller to KONTRONIK is inevitable!

1. update firmware, as usual with ProgUNIT or ProgDISC. Setting the parameters is only possible with the ProgUNIT.

After the update is complete, unplug the drive battery and plug it in again.

3. program mode 1.

Unplug the drive battery and plug it in again. Wait until the controller initializes.

Press and hold the button until the controller beeps (this may take several seconds). The beep of the bootloader update is different from that of the mode programming, so it is easily recognizable.

Unplug the drive battery and plug it in again, the controller initializes and is now ready for user-defined settings.

Version 1.3

  • Graupner motor current warning has been optimized
  • Capacity measurement was optimized

JIVE Pro

JIVE Pro 80+ HV / JIVE Pro 120+ HV

Version 1.14

  • Mode 7 (Reverse rotation) was added
  • JETI protocol has been adapted (now also compatible with R-EX, REX and REX -Assist receivers)
  • Futaba protocol adapted (now also compatible with Futaba CGY760R)
  • KONTRONIK protocol was changed: CRC check adapted

Update JIVE Pro 80+ HV (Version 1.14)
Update JIVE Pro 120+ HV (Version 1.14)

Version 1.13

Bugfix: Graupner HoTT telemetry – capacity limit warning when Bluetooth module is plugged in

Version 1.12

offers its own KONTRONIK protocol for telemetry: KONTRONIK Protocol for Telemetry

Version 1.10

supports the use of the TelMe JETI and MIKADO.

Version 1.9

supports the use of the TelMe Futaba for the FX 22, T18MZ, T18MZ-WC and T14SG.

Version 1.8

supports the use of the TelMe-Futaba.

Version 1.6

  • Alarm parameters programmable via the new K-Konfig interface.
  • automatic pre-commutation has been optimized to reduce the extreme current peaks that occur in some motors.
  • To be able to use the parameters, the new K-Konfig interface is mandatory. If ProgDISC is used, an update must also be performed for it.

KOBY